Previous
Previous Product Image

KL300K33

23,12,20035,07,300
Next

I1002

4,800
Next Product Image

T620

2,250

Elnova Line Interactive UPS using advanced CPU integrated control technology, automatic voltage regulation, which effectively solves the electricity undervoltage, overvoltage, interruption and other power environment problems, provides a reliable power protection for users.

Description

Line Interactive UPS 600VA with Inbuilt Battery

Application

  • Server
  • PC/Workstation
  • Security Monitoring
  • Automatic Control

Features

• Wide input operating range
• Powerful Microprocessor
• Built in AVR
• Surge Suppressor
• Stepped approximation to Sine wave in battery mode
• Cold Start on Battery
• Compact Size
• Short Circuit & Overload protection
• Battery Drain Protection
• Built in Night Charging Mode
• Easy Battery Swappable
• Intelligent Battery Management
• Plug and play (Inbuilt battery model)
• Generator compatible

Electrical Parameters

Model T620 T.620 I1002 X1000 X2000
CAPACITY(VA/W) 600VA/360W 650VA/360W 1000VA/600W 1000VA/600W 2000VA/1200W
INPUT
Input Phase Single Phase
Rated Input Voltage 220/230 Vac
Rated Input Frequency 50HZ/60HZ (Auto sensing)
Input Voltage Range 140-300Vac
Generator Input Yes
OUTPUT
Output Waveform (Batt. Mode) Stepped approximation to Sine wave
AC Voltage Mains Mode 195-255 Vac +5 Vac
AC Voltage Regulation(Batt. Mode) 210-240 Vac/rms
Output Frequency (Batt. Mode) 50 HZ +1 HZ
Transfer Time (Typical) 3-8 ms
BATTERY
Battery TYPE 12V-7AH /9AH External Battery
Battery Quantity (12V DC) 1 1 2 1 2
Typical Load 1 PC 1 PC 2 PC 3 PC 6 PC
Typical Run-time 10-30 Mins. Depend
Recharge Time 6 Hours (90% of Full capacity)
Cold Start Yes
FUNCTION & STANDARD
Protection Function Under/Over Voltage, Spikes, Short Circuit, Overload, discharge, Low battery Cut-off and overcharging protection
Display LED
Alarm Low Battery, Overload, Fault
Auto Restart Yes
Standard IEC/EN62040-1, 62040-2, 62040-3, Complying to CE, BIS
INDICATOR
AC Mode Green Lighting Green Lighting
Battery Backup Mode Green Lighting Yellow Flashing
Fault Mode Continuous Alarm Sound Red Lighting
ENVIRONMENT
Working Temperature Operating: 0-45°C, Storage: – 10°C – 55°C
Relative Humidity/Altitude O to 95% Relative Humidity (Non-condensing) / <1500 M
Noise Low Audible Noise Level
PHYSICAL
Outlet 3 Sockets 4 Sockets
Dimension (DXWXH) mm 279X101X142 87X165X276 320X130X182 395X145X220
Net Weight (kg) 4.4 4 7.8 9 13.55

Shopping cart

0
image/svg+xml

No products in the cart.

Continue Shopping